AMC BIT-100 ( V1.2 ) Filter Integrity Tester
Integtest series filter tester is a specialized instrument for testing the integrity of filter and filtration systems, special bubble point and diffusion flow (forward flow), and for determining the accuracy of filtration system and filter integrity. Test procedures meet FDA requirements, state pharmacopoeia, and GMP for sterilization filters.
Instrument Specifications:
-
Convenient user interface.
-
Diffusion flow value directly from input upstream volume.
-
Automatic control system to minimize the influence of intake air pressure fluctuation on test results.
-
Full automatic control from a PC providing a variety of automated detection function.
-
High accuracy and good reproducibility.
-
Data storage and print test results meet GMP requirements.
Technical support and after-sales services:
Performance parameters
Power requirements: 170-240V AC, 50/60Hz, 85W
Maximum operating pressure: 7999 mbar
Minimum inlet pressure: 3000 mbar
Dimensions: 400 mm x 380 mm x 235 mm
Test pressure range: 500-6900 mbar
Test accuracy: Sensitivity ± 1.0 mbar; Bubble point: ± mbar 75
Operating conditions: Temperature: + 5 °C ~ + 45 °C; Relative humidity: 10-80
Test method and duration: Bubble point test: 10 ± 2 min, Pressure hold test: 8 ± 2 min Diffusion flow test: 10 ± 2min
Print function: Prints test parameters and output results
Historical records: Stores up to 20 groups of testing results
Screen size: 73 x 39mm, monochrome
Language: Chinese
Application:
Disc membrane: Φ25 - Φ300 all sorts of ultrafiltration membrane
Standard cartridge filters (foldable 2.5"- 40”): 1-15 cores
Capsule type filters and mini cartridge filters
AMC BIT-150 ( V3.0 ) Filter Integrity Tester
Bubble point testing by itself does not fully guarantee a filter will completely stop all bacterium it is designed to retain. Therefore it is required to combine the diffusion flow method for comprehensive evaluation to ensure the integrity of the sterile filtration process. In order to meet the strict requirements of the biological pharmaceutical industry for sterile filters, we offer the IntegtestTM BIT-150 full-automatic filter integrity tester. It combines with advanced hardware and software systems along with proprietary artificial intelligence algorithm, allowing it to be capable of automatic testing of diffusion flow and bubble points with higher precision.
Instrument characteristics
-
Computer-controlled automatic detection, bubble point scanning, basic bubble point detection, enhanced bubble point detection, diffusion flow test function.
-
Using advanced apparent diffusion flow analysis principle, the system can achieve test results with better precision and stability. This results in the filter integrity test better conforming with results from bacteria challenging experiments.
-
Double parameter analysis of bubble point value and diffusion flow data ensures high reliability in completeness of filter test results.
-
Internal storage can store up to 500 groups of test results; unlimited storage if connected to a PC.
-
Provides needled printers to print test results allowing for long term records archiving.
-
Online real-time display of pressure and flow curve to help analyze the performance of the filter material and technical parameters.
-
Centralized remote control through data cable connection.
-
5.7" backlight digital LCD with crystal clear display.
-
Popup menu interface allowing easy operation.
Performance parameters
Power requirements: 100-240V AC, 50/60Hz, 100 watts
Maximum operating pressure: 9999 mbar
Minimum inlet pressure: 3000 mbar
Dimensions: 400 mm x 380 mm x 235 mm
Test pressure range: 500-8000 mbar
Precision: et volume test ± 4%, Bubble point: ±50 mbar, Diffusion flow: ± 4%
Operating conditions: Temperature 5-35 °C, Relative humidity: 10-80%
Testing duration: Net volume testing: 2 min ± 1min, Diffusion flow test: 8min ± 2 min
Pure bubble point test: 10 min ± 2 min, Enhance bubble point test: 20 min ± 2 min
Print function: Printable test parameters and results
Historical records function: 500 groups of test results and curves
Screen size: 5.7" TFT; monochrome
Serial connection mode: RS232 serial port
Language: Chinese
AMC BIT-200 ( V4.0 ) Filter Integrity Tester
This integrity tester is specifically designed using the water immersion method for hydrophobic filters, thus solving the problem that hydrophobic filters can only be used after being infiltrated with organic solvents. This is a significant improvement over the existing technologies found in China.
Instrument characteristics
-
Advanced testing functions based on the water immersion method, solving the problem of hydrophobic filters only being used after being injected with organic solvents.
-
Advanced automatic control systems, controlling air pressure without manual adjustment to ensure testing accuracy and precision.
-
Real-time display of test data shown in graphical output to assist in monitoring test processes.
-
Dual-core calculation within the PC controller software.
-
Offers all testing functions found in similar international instruments.
-
Provides excellent management functionalties for user-side systems including the option to change password.
-
Capable of automatic protection for the filters being tested to avoid filter damage due to possile overvoltage during tests.
-
Options for automatic printing feature for user’s convenience.
-
5.7” crystal-clear backlit digital LCD
-
Available features for testing wafer diffusion flow; a significant function for identifying membrane filter characteristics.
Performance parameters
Power requirements: 100-240V AC, 50/60Hz, 100 watts
Maximum operating pressure: 9999 mbar
Minimum inlet pressure: 3000 mbar
Dimensions: 400 mm x 380 mm x 235 mm
Test pressure range: 500-6900 mbar
Precision: Net volume test ± 4%, Bubble point: ±50 mbar, Diffusion flow: ± 4%
Water immersion method: ± 0.06 ml
Operating conditions: 5-35 °C, 10-80% relative humidity
Test duration: Net volume testing: 5 min ± 2 min, Diffusion flow test: 8min ± 2 min
Pure bubble point test: 15 min ± 2 min
Enhance bubble point test: 20 min ± 2 min
Water immersion test: (Preset test time + 5 min) ± 2 min
Print function: Automatic printing, wide printing test parameters/results in Mandarin
Records function: 500 groups of test results and curves, option 1000 test results
Screen size: 5.7" TFT; monochrome
Serial connection mode: RS232 serial port
Language: Chinese/English
|