Materials of Construction |
Filter Media: |
Pleated non-woven polypropylene |
Support Material: |
Polypropylene |
Structure Components: |
Polypropylene |
Sealing Technology: |
Thermal bonding |
|
Dimensions |
Nominal Length: |
10, 20, 30 and 40 inch
(25.4, 50.8, 76.2 and 101.6 cm) |
Diameter: |
2.7 inches (6.9 cm) |
|
Nominal Pore Sizes |
0.2, 0.45, 1, 3, 5, 10, 30, 60 μm |
|
Typical Effective Filtration Area |
0.2, 0.45, 1 μm: 5 ft² (0.5 m²) per 10 inch
3, 5, 10 μm: 6 ft² (0.6 m²) per 10 inch
30, 60 μm: 7 ft² (0.7 m²) per 10 inch |
|
Maximum Operating Temperature |
82℃ (182℉) at 10 psi (0.7 bar) |
(Supported adapters are recommended for applications at elevated temperature over 60°C)
|
|
Sterilization/Sanitization Methods |
Autoclave: |
121℃ (250℉) for 30 minutes up to 30 cycles |
In-line Steam: |
134℃ (273℉) for 60 minutes at 3 psi (0.21 bar) maximum differential pressure |
|
Maximum Differential Forward Pressure |
60 psi (4.1 bar) 60 psi (4.1 bar) at ambient temperature |
|
Maximum Differential Back Pressure |
40 psi (2.8 bar) at 60℃ (140℉) |
|
Maximum Continuous Pressure |
Limited by housing |
Typical Water Flow Rate
.jpg)
Typical Air Flow Rates (10 inch length)
.jpg)
0.2 μm Filter Retention Efficiency vs. Particle Size
.jpg)
0.45 μm Filter Retention Efficiency vs. Particle Size
.jpg)
1 μm Filter Retention Efficiency vs. Particle Size
.jpg)
3 μm Filter Retention Efficiency vs. Particle Size
.jpg)
5 μm Filter Retention Efficiency vs. Particle Size
.jpg)
10 μm Filter Retention Efficiency vs. Particle Size
.jpg)
30 μm Filter Retention Efficiency vs. Particle Size
.jpg)
60 μm Filter Retention Efficiency vs. Particle Size
.jpg)